Wireless Smoke/Heat Detector

  • Wireless
    FACP
  • Wireless Fire
    Alarm Module
  • Wireless Fire
    Detector

With Allse specialized fire prevention /detection/alarming technology
We will save your assets from fire

Diagram
Diagram

Three major Technology

  • 01Easy install and accurate detecting Wireless detection technology

  • 02Accurate technology of identifying non -fire alarm Technology for reducing Non-fire alarm

  • 03Swift monitoring and reporting of the accident IoT platform technology

Merits

  • 01Specialized fire detector

    - Wireless fire detector, needless of plumbing work

    - Use low power wireless telecommunication LPWA

    - Detect appropriate Co2, temperature, and humidity Considering building trait

  • 02Non-fire detection differentiated from ther companies

    - Detector dark room technology

    - Self supplementary algorithm

    -Wireless detector + Independent detector integrated detecting

  • 03IoT based Disaster safety platform

    - Dashboard service

    - Situation alarming service

    - Smart phone app service

Wireless detecting technology

  • 01Fire detection without wire

    - With simple installation without plumbing work, you can use and manage

     · Apply wireless detecting technology, no need for plumbing, you can install, operate without complex construction

  • 02Accurate fire detection

    - Detect fire accurately with differentiated various detecting technology

     · With ALLLITELIFE’s specialized detecting technology, we provide accurate fire detection

  • 03Low power wireless telecommunication

    - With low consumption power telecommunication, easy for installation and management

     · With low power consumption telecommunication (LPWA) method, you can use for 2 years without battery replacement

Construction cost for detector

Detector construction cost Detector construction cost

Construction cost in total

Total construction cost Total construction cost

Applying wireless technology, as of installing one analog detector
Available to reduce 86% of construction costs

IoT platform technology

  • 01SK Infosec Secudium IoT platform base

  • 02Dashboard service Status monitoring service provision

  • 03Control room service when emergent situation happens, provide immediate alarm and mobilization service

  • 04Smart Phone App alarming Service

Wireless fire detectors on IoT based products

Diagram
Diagram
  • 01As for the areas equipped with old fire fighting facilities, we realize fire patrol control system applying ‘LPWA(Low Power wide Rea Network)’ based on Internet of Small Things

  • 02Linked with smartphones, PC, real-time prevention and pre-emptive prevention possible at anytime, anywhere for fire detection monitoring

  • 03IoT platform service based wireless detector provide diverse product lines based on installation area, purpose of detection

Independent wireless detector – Sensorway

Diagram
Diagram
  • 01Convenience

    - Connect to Internet Switching hub

  • 02Smart phone Application alarming service

  • 03Non-fire monitoring available

    - Constant monitoring of temperature, CO, CO2, humidity, and smoke concentration

  • 04Expandability

    - Possible to connect with ventilation and air purification afterwards

Composition of wireless fire detecting system

Diagram
Diagram

Current equipment does not prevent arc electric fires.
allse offers an arc monitoring system to protect your precious property.

Arc monitoring diagram

Arc monitoring Diagram
Diagram

Domestic regulations related to arc fire

Classification Category Current regulations Note
Electricity Laws
(Electrical Equipment Technical Standard)
Earth leakage breaker Shut off when sensitivity current is over 30mA Non-operational below 30 mA
Overcurrent blocking (30A) 1.6 times rated current: cut off after 60 minutes
Twice the rated current: Cut off after 2 minutes
Regulation set about 40 years ago
Can not be blocked when an arc occurs

Electricity Laws
(Electrical Equipment Technical Standard)

Category Current regulations Note
Earth leakage breaker Shut off when sensitivity current is over 30mA Non-operational below 30 mA
Overcurrent blocking (30A) 1.6 times rated current: cut off after 60 minutes
Twice the rated current: Cut off after 2 minutes
Regulation set about 40 years ago
Can not be blocked when an arc occurs

Arc fire prevention is impossible with existing domestic laws

Classification Category Current regulations Note
Fire Laws
(Fire Safety Standards)
Fire monitoring Only standards for heat, smoke, and flame No early fire monitoring

Fire Laws
(Fire Safety Standards)

Category Current regulations Note
Fire monitoring Only standards for heat, smoke, and flame No early fire monitoring

Detection order

Detection order
Diagram

Leakage monitoring alarm system that provides step-by-step alarms for monitoring the pressure of building fire-fighting water systems (spring sprinklers, fire hydrants).

Diagram

Diagram
Diagram

Four core technologies for water monitoring system

  • 01Proper pressure calculation algorithm technology

    - Alarm valve malfunction prevention
    - Prevents sprinkler malfunction due to narrowing of the clapper inside the alarm valve

  • 02Sprinkler measurement data monitoring

    - Application of integrated maintenance management system for computer equipment through ITSM
    - Optimal manpower considering professionalism and continuity

  • 03Set appropriate values through algorithm according to site situation

    - Set proper value by apartment building and floor

  • 04Implementation of predictive alarm system for each stage through pressure change monitoring

    - Predictable by step rather than simple close contact method of existing alarm valves

Water monitoring system designed from the perspectives of management and facility maintenance

  • 01Affordable maintenance

    - Reduced leakage detection cost
    - Reduced maintenance cost for pressure maintenance pump
    - Reduced household repair costs due to leakage

  • 02Self maintenance

    - Simple exchange method
    - Located in fire hydrant and alarm valve room

  • 03Early alarm function

    - Response time in case of fire
    - Step by step prediction

  • 04Minimum power consumption

    - Reduced battery cost

  • 05Quality reliability guarantee

    - Use of product for more than 10 years

allse-RF3.0P_Compound

Wireless R Type Fire Alarm Control Panel

제품이미지

Product view

View
Type AC 220V, DC 24V, LCD type, wired/wireless type, indoor/outdoor fire hydrant facilities
Type approval No 수24-6
Rated Voltage AC220V, DC24V
Connectable fire alarm bell quantity DC24V 50mA X 20EA
Auxiliary power DC12V, 4Ah X 2EA(Lead acid battery)
Maximum Quantities for One Loop (Wireless 24 + Wired 424) /per system
Connectable detector 감19-67,감19-68
lines for wired 20 lines
No of lines for wireless 20 wireless

allse-RF3.0P

Wireless R Type Fire Alarm Control Panel

제품이미지

Product view

View
Type AC 220 V, DC 24 V, LCD, wired/wireless
Type approval No 수20-14
Output capacity DC 24V, 1A
Maximum quantity of connectable wireless detector 20
Main power Rated Input Power 24V
Output capacity 1A
KC ID R-CS rP3-all-RF44-1
Connectable Detector 감19-67,감19-68
lines for wired 20 lines
No of lines for wireless 20 wireless

Wall Mounted Type 500 ~ 1,000 circuits

제품이미지

Product view

View
Classification GR Type Fire Alarm Control Panel
Type AC220V, DC 24V, LCD, semiconductor, digital, storage/nonstorage(Indoor outdoor fire hydrant, sprinkler) equipment, (water spray, foam) extinguishing equipment, smoke control equipment
Type approval No 수24-18
Rated Voltage AC220V, DC24V
Connectable fire alarm bell quantity DC24V 50mA X 20EA
Gas leakage alarm Use of gas leakage alarm with zero voltage contact signal output when operating
Auxiliary power DC12V, 4Ah X 2EA(Lead acid battery)
Local communication method PW control method
Network communication method 2Wire TCP/IP or optical communication
Maximum Quantities for One Loop Up to 10 / per line
Connectable addressable module 중19-24,중19-25,중19-26
Maximum Quantities of Transponders 508 lines/per system
Material and color Default black 1.6t *custom color available at your request

Wireless Addressable Module

제품이미지

Product view

View
Type DC24V, GR type, wireless input 20 Circuit,
Type approval No 중24-17
Output capacity DC 24V, 1A
Maximum quantity of connectable wireless detector 20
Main power Rated Input Power 24V
Output capacity 1A
Connectable Control Panel 수24-18

Wireless fixed temperature spot detector

제품이미지
View
Type DC3V, 2 type, analog type, standard, restorable, Nominal Sensing Temperature Range (60 ℃ ~ 80℃)
Type name Allse-AD3H_2A
Type No 감 24-57
Rated Voltage DC 3 V
Ambient Temperature & Humidity (temperature) : -10~50℃ / (humidity) : 10~95℃
Current consumption 20mA at fire detection
Sensing mode Nominal working temperature point detection by semiconductor
Color and weight Ivory white/140g

Wireless photoelectric spot detector

제품이미지

Product view

View
Type DC3V, 2 type, analog type, standard, restorable,Nominal Sensing Concentration Range ( 5%/m~ 17%/m)
Type name Allse-AD3S_2A
Type No 감 24-58
Rated Voltage DC 3 V
Ambient Temperature & Humidity (temperature) : -10 ~ 50℃/ (humidity) :10 ~ 95%
Current consumption 20mA at fire detection
Sensing mode Scattered light detection by smoke with 15% photosensitive rate
Color and weight Ivory white / 120g